CF Series Forward Curved Impellers Centrifugal Fan Blower
CF Series centrifugal fan is often used in kitchen exhaust and fume extraction, suitable for ventilation and fume extraction in public places such as canteen, hotel, restaurant , and so on.
 
            CF Series centrifugal fan is often used in kitchen exhaust and fume extraction, suitable for ventilation and fume extraction in public places such as canteen, hotel, restaurant , and so on.
 
            The FC series industrial window exhaust fan is compact in design, small in size and light in weight, and is especially suitable for arrangement in limited space.
 
            The SF Series tube axial fan is an efficient, low noise ventilation equipment, widely used in a variety of ventilation, heat dissipation and noise control scenarios.
Guangdong Gaoze Ventilation Equipment Co.,Ltd.
Moveable Ventilator Blower Fan

1.Typical Feature and Application
The Movable exhaust fan is installed with a auxiliary pulley, which can be moved and placed, convenient and flexible, and can realize positive and reverse two-way ventilation  under the same installation position.
The Movable exhaust fan is designed with optimized aerodynamic principles and manufactured with advanced processing technology.
The Movable exhaust fan structure is reasonable, sturdy, safe and practical. With adjustable aluminum alloy impeller, body high temperature paint, not easy to fade.
The Movable exhaust fan has 400mm, 500mm, 600mm, 700mm, 800mm, 900mm, 1000mm, can be customized different sizes.
2. Performance Range
| Fan Type | Moveable Ventilator Blower Fan | 
| Certificate | CE,CCC | 
| Electricity Current Type | AC(Alternating Current) | 
| Voltage | 220/380V | 
| Frequency | 50HZ | 
| Power | 0.55KW-7.5KW | 
| Speed | 960-2900RPM | 
| Air Volume | 4800m³/h up to 46950 m³/h | 
| Motor | Standard Motor | 
3.Product Description
 
Designed for use in factory buildings, warehouses, workshops and more, this movable exhaust fan features a lightweight metal frame and universal brake rollers for stable movement and flexible steering. The mobile fan adopts aluminum alloy blades and 100% pure copper motor, which can output 5300-18570m³/h strong air volume and rapidly improve air circulation.
The mobile fan is not only simple to operate but also very durable. The emergency stop button can be optional. In case of emergency, the power supply can be cut off by one button to double the safety guarantee. The mobile fan is equipped with a protective net to prevent foreign bodies from entering, and the IP44 protective structure responds to daily dust and water mist erosion.
The standing ac fan is suitable for equipment cooling, local cooling, welding gas dilution and other scenarios, with high cost performance and reliable performance, and has become a practical choice for small and medium-sized industrial ventilation.
4.Fan Operation
Before using the movable exhaust fan, check whether the mobile fan is damaged or deformed due to packaging and transportation. If it is damaged and deformed, repair it before using it.
Turn on the power to the mobile fan and ensure that the mobile fan is working properly.
Hold the handle of the mobile fan by hand and adjust its direction so that it rotates towards the area that needs to be ventilated.
5.Fan Maintain
Ensure that the mobile fan can operate under normal use environment.
Regularly check whether the blade of the mobile fan is loose and whether the clearance between the blade and the air duct is normal.
The mobile fan needs to periodically check the fastening environment of the connection bolts between the motor and the housing, and check whether the vibration absorbing seat and the base are connected properly.
The mobile fan needs to remove the ash and dirt of the blade on schedule.
6.Technical Specification
| Model (No.) | Voltage | Frequency | Power | Revolution | Air Flow | Wind pressure | 
| (V) | (HZ) | (KW) | (rpm) | (m3/h) | (Pa) | |
| 4G | 220/380 | 50 | 1.1 | 2900 | 6860 | 330 | 
| 220/380 | 50 | 0.75 | 1450 | 5600 | 170 | |
| 220/380 | 50 | 0.55 | 1450 | 4850 | 160 | |
| 5G | 220/380 | 50 | 2.2 | 2900 | 15300 | 310 | 
| 220/380 | 50 | 1.5 | 1450 | 10400 | 210 | |
| 220/380 | 50 | 1.5 | 2900 | 6860 | 430 | |
| 220/380 | 50 | 0.75 | 1450 | 4800 | 210 | |
| 6G | 220/380 | 50 | 1.5 | 1450 | 14500 | 200 | 
| 220/380 | 50 | 2.2 | 1450 | 16500 | 220 | |
| 380 | 50 | 3 | 2900 | 20100 | 506 | |
| 380 | 50 | 4 | 2900 | 21650 | 540 | |
| 7G | 380 | 50 | 2.2 | 1450 | 18570 | 285 | 
| 380 | 50 | 1.5 | 960 | 16580 | 195 | |
| 380 | 50 | 5.5 | 2900 | 24100 | 585 | |
| 8G | 380 | 50 | 3 | 1450 | 23300 | 305 | 
| 380 | 50 | 4 | 1450 | 25300 | 330 | |
| 380 | 50 | 2.2 | 960 | 18600 | 265 | |
| 9G | 380 | 50 | 5.5 | 1450 | 33180 | 390 | 
| 380 | 50 | 3 | 960 | 30223 | 305 | |
| 10G | 380 | 50 | 7.5 | 1450 | 46950 | 475 | 
| 380 | 50 | 4 | 960 | 36310 | 325 | 
7.Packing Detail
Film Packing: a cost-effective packing method, it is suggested when order is one full container.