T40-A Industrial Smoke Ventilation Fan

  • T40-A Industrial Smoke Ventilation Fan
  • T40-A Industrial Smoke Ventilation Fan
  • T40-A Industrial Smoke Ventilation Fan
  • video
  • YUTON
  • GUANGDONG, CHINA
T40 Series industrial blower has a wide range of applications, suitable for general factories, warehouses, offices, residential and other places to ventilate or strengthen heating heat dissipation.
Our Products

Guangdong Gaoze Ventilation Equipment Co.,Ltd.



T40-A Industrial Smoke Ventilation Fan

industrial blower

1.Typical Feature and Application


  • The impeller of the T40 industrial blower adopts an integrated hub structure, combined with aerodynamic optimization of the blade, the air output is stable and efficient, and the energy consumption is reduced by 15%-20%.

  • The T40 industrial blower is made of high-quality iron material, the wheel hub and the blade are formed together, the structure is stable, the long-term operation is not deformed, and the equipment life is more than 8 years.

  • T40 industrial blower with 100% copper motor, high efficiency, energy saving, durable, low noise, high stability.T40 industrial blower can be made into explosion-proof axial flow fan, using explosion-proof motor and aluminum alloy blades, can be customized according to customer requirements.

  • This T40 axial fan blower has 300mm, 350mm, 400mm, 500mm, 600mm, 700mm, 800mm, 900mm, 1000mm, 1200mm ten different sizes.




2. Performance Range


Fan Type

T40-A Industrial Smoke Ventilation Fan

Certificate

CE,CCC

Electricity Current Type

AC(Alternating Current)

Voltage

220V/380V

Frequency

50HZ

Power

0.25KW-7.5KW

Speed

2900 to 960 RPM

Air Volume

2000m³/h up to 44731 m³/h

Motor 

Standard Motor



3.Product Description


       The T40 series industrial blower is an energy-efficient device designed for industrial ventilation, agricultural cooling and commercial environments, with stable performance and durability as the core advantages.The impeller of the T40 industrial blower is directly mounted on the motor shaft and adopts a directly connected structure. The impeller of the T40 industrial blower consists of a blade made of thin steel plate and a hub welded to the hub at a selected Angle.

       The T40 tube axial exhaust fan adopts a modular structure to support horizontal, vertical or inclined installation, and the protective mesh cover can be quickly removed and cleaned for easy daily maintenance. Its rugged steel impeller is highly anti-fouling and requires only a simple wipe to maintain efficient operation, significantly reducing maintenance costs.

       T40 series industrial blower covers the size of 3A to 12A, the power range is 0.25KW-7.5KW, support 220V/380V voltage customization, flexible to meet the needs of small workshops, warehousing logistics, agricultural greenhouses and other diverse scenarios.



4.Fan Operation


  • Check whether the T40 axial extractor fan is in good condition and matches the model, power, and application scenario.

  • Ensure that the installation position of the T40 heavy duty industrial fan is well ventilated and the air outlet is not blocked.

  • Select the direction as required, fasten the base of the T40 heavy duty industrial fan with a bracket or wall with bolts, and install anti-vibration gaskets to reduce vibration.

  • By professional electricians according to the T40 heavy duty industrial fan nameplate voltage (220V/380V) on the power supply, install leakage protection device.

  • Monitor the noise of T40 heavy duty industrial fan operation. If there is metal friction or abnormal vibration, stop the machine immediately to check the balance of the impeller.



5.Fan Maintain


  • The air flowing through the T40 heavy duty industrial fan is clean and dry, and must not be mixed with impurities and excessive water vapor.

  • When the T40 heavy duty industrial fan is reused after being idle for a long time, it must check whether the connected parts are firm and reliable, whether the rotation is flexible, and can be formally used after the test.

  • Daily attention T40 heavy duty industrial fan in the operation of whether abnormal sound, vibration is increased, found abnormal situation, should be promptly shut down maintenance.

  • The dust and dirt on the blades of the T40 heavy duty industrial fan should be cleaned in time.



6.Technical Specification


Model

(No.)

Voltage

PowerRevolutionAir FlowWind pressureNoiseWeight
(V)(KW)(rpm)(m3/h)(Pa)
(dB)A(KG)
3A220/3800.2514502000526416
220/3800.5529004650

300

7120
3.5A220/380
0.3714503000826520
220/3800.75290065403807322
4A220/3800.55145046001306723
220/3801.1290082304388126
5A3800.75145080501506930
3801.5145093001967232
3802.22900118325158635
6A38032900235004508952
3802.21450150002607848
3800.75960109001177246
7A38031450185102808165
3801.5960175001587360
8A380414503668044083
72
3802.2960256132107570
9A3805.514503880041579130
38039603523026686125
10A3805.59604218031279150
12A3807.59604473136082195



7.Packing Detail


Film Packing: a cost-effective packing method, it is suggested when order is one full container.

Plywood Box Packing: more safe packing, it is suggested when order is not enough one full container.





Get the latest price? We will reply as soon as possible (within 12 hours)